Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
BMC Neurol ; 24(1): 111, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575854

RESUMO

BACKGROUND: Rapamycin is an inhibitor of the mechanistic target of rapamycin (mTOR) protein kinase, and preclinical data demonstrate that it is a promising candidate for a general gero- and neuroprotective treatment in humans. Results from mouse models of Alzheimer's disease have shown beneficial effects of rapamycin, including preventing or reversing cognitive deficits, reducing amyloid oligomers and tauopathies and normalizing synaptic plasticity and cerebral glucose uptake. The "Evaluating Rapamycin Treatment in Alzheimer's Disease using Positron Emission Tomography" (ERAP) trial aims to test if these results translate to humans through evaluating the change in cerebral glucose uptake following six months of rapamycin treatment in participants with early-stage Alzheimer's disease. METHODS: ERAP is a six-month-long, single-arm, open-label, phase IIa biomarker-driven study evaluating if the drug rapamycin can be repurposed to treat Alzheimer's disease. Fifteen patients will be included and treated with a weekly dose of 7 mg rapamycin for six months. The primary endpoint will be change in cerebral glucose uptake, measured using [18F]FDG positron emission tomography. Secondary endpoints include changes in cognitive measures, markers in cerebrospinal fluid as well as cerebral blood flow measured using magnetic resonance imaging. As exploratory outcomes, the study will assess change in multiple age-related pathological processes, such as periodontal inflammation, retinal degeneration, bone mineral density loss, atherosclerosis and decreased cardiac function. DISCUSSION: The ERAP study is a clinical trial using in vivo imaging biomarkers to assess the repurposing of rapamycin for the treatment of Alzheimer's disease. If successful, the study would provide a strong rationale for large-scale evaluation of mTOR-inhibitors as a potential disease-modifying treatment in Alzheimer's disease. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT06022068, date of registration 2023-08-30.


Assuntos
Doença de Alzheimer , Transtornos Cognitivos , Animais , Camundongos , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/complicações , Envelhecimento , Tomografia por Emissão de Pósitrons/métodos , Glucose/metabolismo , Serina-Treonina Quinases TOR , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Ensaios Clínicos Fase II como Assunto
2.
Acta Neuropathol Commun ; 12(1): 37, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429841

RESUMO

Leber's hereditary optic neuropathy (LHON) is driven by mtDNA mutations affecting Complex I presenting as progressive retinal ganglion cell dysfunction usually in the absence of extra-ophthalmic symptoms. There are no long-term neuroprotective agents for LHON. Oral nicotinamide provides a robust neuroprotective effect against mitochondrial and metabolic dysfunction in other retinal injuries. We explored the potential for nicotinamide to protect mitochondria in LHON by modelling the disease in mice through intravitreal injection of the Complex I inhibitor rotenone. Using MitoV mice expressing a mitochondrial-tagged YFP in retinal ganglion cells we assessed mitochondrial morphology through super-resolution imaging and digital reconstruction. Rotenone induced Complex I inhibition resulted in retinal ganglion cell wide mitochondrial loss and fragmentation. This was prevented by oral nicotinamide treatment. Mitochondrial ultrastructure was quantified by transition electron microscopy, demonstrating a loss of cristae density following rotenone injection, which was also prevented by nicotinamide treatment. These results demonstrate that nicotinamide protects mitochondria during Complex I dysfunction. Nicotinamide has the potential to be a useful treatment strategy for LHON to limit retinal ganglion cell degeneration.


Assuntos
Atrofia Óptica Hereditária de Leber , Rotenona , Camundongos , Animais , Rotenona/toxicidade , Rotenona/metabolismo , Niacinamida/efeitos adversos , Niacinamida/metabolismo , Mitocôndrias/metabolismo , Células Ganglionares da Retina , Atrofia Óptica Hereditária de Leber/genética , Atrofia Óptica Hereditária de Leber/metabolismo , Atrofia Óptica Hereditária de Leber/terapia , Complexo I de Transporte de Elétrons/metabolismo
3.
Artigo em Inglês | MEDLINE | ID: mdl-38085173

RESUMO

PURPOSE: To evaluate the repeatability of a new swept source optical coherence tomography (SS-OCT) based biometer to measure anterior segment parameters, and to assess the agreement with three other imaging devices based on different measurements principles. SETTING: Unit of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institutet, Sweden. DESIGN: Prospective, comparative case series. METHODS: 3 consecutive measuremetns were obtained in unoperated eyes with the Eyestar900 (SS-OCT), Lenstar 900, MS-39, and Sirius. The following anterior segment parameters were evaluated: central corneal thickness (CCT), corneal diameter (CD), aqueous depth (AQD), and corneal power metrics. The repeatability limit (Rlim), coefficient of variation (CoV), and a repeated measures Bland-Altman analysis were performed. RESULTS: 74 eyes of 74 participants were measured. The Rlims for CCT, CD, and AQD were lower than 10µm, 0.3mm, and 0.10mm for all devices, respectively. The corresponding CoVs for these parameters never exceeded 1.2%. The Rlim for the corneal power metrics never exceeded 0.60D for any of the instruments. Lenstar showed the best agreement with the MS-39 to measure CCT, CD, and AQD (limit of agreement interval, LoA: 15.54µm, 0.55mm, and 0.16mm, respectively). The mean difference for keratometry parameters was lower than 0.3D for all device comparisons, and the LoA interval ranged between 0.52D to 1.21D. CONCLUSIONS: The repeatability for measuring anterior segment parameters was good, and the agreement among all the instuments was good for CD and AQD measurements. However, for CCT and keratometer parameters, the instruments cannot be used interchangeably due to large LoA interval.

4.
Afr Health Sci ; 23(1): 137-148, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37545934

RESUMO

Purpose: The present study investigated the integrity of contrast sensitivity (CS), colour vision, and pattern evoked vision potentials (VEP) in non-immunocompromised people living with HIV (NIPLHIV) without retinitis. Methods: All participants were visually asymptomatic and no history of ocular disorders, with CD4 counts above 350 cells/mm3, low viral loads and on ART. Thirty NIPLHIV and 30 age-matched HIV negative control groups underwent F100 hue colour assessment, Pelli-Robson contrast sensitivity assessment and pattern-reversal VEP. Results: The median F100 total error scores for NIPLHIV and controls was 33 (IQR: 28;41) and 28 (IQR: 26;48.50) respectively, this was statistically different (p= 0.020). The median P100 amplitude for NIPLHIV was 5.75 µV (IQR: 4.4;8.85) and 4.05 µV (IQR: 3.2;5.8) for controls, this was statistically different (p=0.045). The mean LogCS score 1.83±0.14 and the median P100 peak latency was 105.45 msec (IQR: 102.98;108.98) for NIPLHIV. Higher CD4+ counts were significantly associated with having higher F100 total error scores (OR=0.995; p=0.018), lower P100 amplitudes (OR=1.007; p=0.010) and higher P100 latencies (OR=0.994; p=0.011). Conclusion: Contrast sensitivity function, colour vision, and VEP were uncompromised in NIPLHIV. Associations between CD4 counts with F100 total error scores and P100 latency may aid in the surveillance of vision of NIPLHIV.


Assuntos
Infecções por HIV , Retinite , Humanos , Potenciais Evocados Visuais , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico
5.
Eye Vis (Lond) ; 10(1): 24, 2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37264436

RESUMO

BACKGROUND: To evaluate the repeatability of a fully automated swept-source optical coherence tomography (SS-OCT) and its agreement with an optical low coherence reflectometry (OLCR) for several biometric parameters. METHODS: In this study, 74 eyes of 74 patients were measured using the Eyestar 900 SS-OCT and Lenstar LS 900 OLCR. Flat keratometry (K1) and steep keratometry (K2), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were measured three times with each device. The repeatability was analyzed with the intrasubject standard deviation, coefficient of variability (CoV), and coefficient of repeatability (CoR) for each instrument. The agreement between the instruments was evaluated with Bland-Altman analysis. RESULTS: K1, K2 and CCT CoV values were < 0.2%, < 0.4% and < 0.55%, respectively. Higher CoV values were found for ACD and LT ranging from 0.56% to 1.74%. The lowest CoV values were found for the AL measurements (0.03% and 0.06% for the Eyestar 900 and the Lenstar LS 900, respectively). AL measurements provided the highest repeatability, measured with both CoV and CoR values, and the CCT was the parameter with the lowest repeatability. The CCT and LT measurements were statistically significant between the two biometers (P < 0.001). The interval of the limits of agreement was < 0.6 D for K1 and K2, 15.78 µm for CCT, 0.21 mm for ACD, 0.34 mm for LT, and 0.08 mm for AL. CONCLUSIONS: Both biometers provide repeatable measurements for the different parameters analyzed and can be used interchangeably.

6.
Eye (Lond) ; 37(11): 2204-2211, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36434284

RESUMO

BACKGROUND: Visual outcomes after primary tumour treatment of uveal melanoma (UM) have been investigated repeatedly. This study evaluates the correlation between best-corrected visual acuity (BCVA) before treatment with clinicopathological factors and patient survival. SUBJECTS/METHODS: Pre-treatment BCVA was examined in relation to tumour dimensions and location, and survival in a retrospective cohort of 1809 patients who underwent plaque brachytherapy. BCVA was also correlated to tumour histological factors in a second cohort of 137 enucleated eyes. RESULTS: The mean BCVA of the tumour eye prior to plaque brachytherapy was LogMAR 0.42 (SD 0.46). Patients with low BCVA (LogMAR ≥ 1.00) did not differ in age (p = 0.19) and had similar frequency of ciliary body involvement (p = 0.99) but had tumours with greater apical thickness (p < 0.0001), greater diameter (p < 0.0001) and shorter distance to the optic disc and fovea (p < 0.0001). There were no significant relations between low BCVA and any of 13 examined tumour histological factors at a Bonferroni-corrected significance level (p > 0.004). Patients with low BCVA had greater incidence of UM-related mortality in competing risk analysis (p = 0.0019) and shorter overall survival (p < 0.0001). Low BCVA was also associated with increased hazard ratio (HR) for UM-related mortality in univariate analysis (HR 1.5, 95% confidence interval 1.2 to 1.9), but not in multivariate analysis with tumour size and location as covariates. CONCLUSIONS: UM patients with low BCVA before primary tumour treatment have a worse prognosis, likely related to increased tumour dimensions. Future studies should examine the prognostic significance of BCVA in relation to macula-involving retinal detachment and genetic factors.


Assuntos
Macula Lutea , Neoplasias Uveais , Humanos , Prognóstico , Estudos Retrospectivos , Neoplasias Uveais/patologia , Acuidade Visual , Macula Lutea/patologia
7.
PLoS One ; 17(11): e0278269, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36441778

RESUMO

PURPOSE: To evaluate the precision of objective refraction measurements with six different autorefractors that have different designs and measurement principles and to compare the objective refraction values with the subjective refraction. METHOD: Objective refraction of 55 participants was measured using six autorefractors with different designs. The instrument features mainly varied in terms of measurement principles, inbuilt fogging, open or closed view, and handheld or stationary designs. Two repeated measurements of objective refraction were performed with each autorefractor. The objective refractions from the six autorefractors were compared with the standard subjective refraction. The repeatability limit and Bland-Altman were used to describe the precision and accuracy of each autorefractor, respectively. The analysis was done using the spherical component of the refraction and the power-vector components, spherical equivalent (M), and cylindrical vectors. RESULTS: The repeatability of all autorefractors was within 1.00 and 0.35D for measuring the M and both cylindrical components, respectively. Inbuilt fogging was the common feature of the instruments that showed better repeatability. Compared to subjective refraction, the mean difference for sphere and M was below +0.50D, and it was close to zero for the cylindrical components. The instruments that had inbuilt fogging showed narrower limit of agreement. When combined with fogging, the open field refractors showed better precision and accuracy. CONCLUSIONS: The inbuilt fogging is the most important feature followed by the open view in determining the precision and accuracy of the autorefractor values.


Assuntos
Erros de Refração , Humanos , Animais , Erros de Refração/diagnóstico , Testes Visuais , Refração Ocular , Tempo (Meteorologia) , Vetores de Doenças
8.
Sci Rep ; 12(1): 566, 2022 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-35022479

RESUMO

The similarities between horizontal and vertical Optical Coherence Tomography (OCT) scans for the individual retinal layer thickness measurements in the macula was evaluated. Two volumetric scans (B-scans oriented horizontally and vertically) were performed in 64 multiple sclerosis subjects with history of unilateral optic neuritis and 64 healthy controls. The agreement between the thickness measurements with horizontal and vertical OCT scans was evaluated in 3 groups of eyes: healthy controls, eyes with history of optic neuritis and the fellow eyes. The mean difference in individual layer thickness between the scans was smaller than the instrument's axial resolution in all 3 groups. The limit of agreement (LoA) varied among the different layers and sectors analyzed and this trend was similar in all the groups. For the inner retinal layers (retinal nerve fiber layer to inner nuclear layer), the inner macular sectors had a larger LoA compared to the corresponding outer sectors. In the outer plexiform and nuclear layers, the central and inner sectors (except inner temporal) had LoA larger than the other sectors and layers. The larger LoA seen for different layers and sectors suggests that the scan direction must be same for the follow-up OCT measurements and in clinical studies.


Assuntos
Esclerose Múltipla/diagnóstico por imagem , Neurite Óptica/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Neurite Óptica/etiologia
9.
Ophthalmic Physiol Opt ; 42(2): 393-409, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35023204

RESUMO

BACKGROUND: This study sought to establish the association between retinal morphology, visual function and linear parameters of cerebral atrophy in non-immunocompromised people living with HIV (NIPLHIV). METHODS: Sixty participants (30 NIPLHIV, 30 controls), aged 18-45 years, were sourced from an outpatient clinic in South Africa. NIPLHIV on antiretroviral therapy (ART) had elevated CD4 counts and low viral loads. Macula thickness and volume measurements were obtained using the Spectralis optical coherence tomographer. Contrast sensitivity (CS), colour vision and visual-evoked potentials (VEP) were also obtained. Linear parameters of cerebral atrophy (Sylvian fissure ratio, SFR) and bicaudate nucleus ratio (BCR) were all acquired from computed tomography (CT) scans. Associations between retinal thickness and volume and visual function were established by principal component factor analysis. RESULTS: CS scores were indirectly associated with the Inner Nuclear Layer (INL)-ETDRS thickness and volume subfields (co-efficient = -0.07; p = 0.02 and -0.11; p = 0.001), respectively. F100 total error scores (TES) were directly associated with the thicknesses of Ganglion Cell Layer-ETDRS subfields (co-efficient = 6.06; p = 0.04) but indirectly associated with INL-ETDRS subfields (co-efficient = -5.49; p = 0.04). F100-TES were indirectly associated with volumes of RNFL (Retinal Nerve Fibre Layer)-ETDRS subfields (co-efficient = -5.54; p = 0.02) and inner retina -ETDRS subfields (co-efficient = -6.70; p = 0.02). P100 latency was directly associated with RNFL-ETDRS subfield thickness (co-efficient = 2.90; p = 0.02) and volumes of outer retina subfields (co-efficient = 2.72; p = 0.04). CS scores were directly associated with SFR (co-efficient = -0.04; p = 0.01). F100-TES were directly associated with BCR (co-efficient = 0.003; p = 0.004) and SFR (co-efficient = 0.002; p = 0.02). P100 latency was indirectly associated with BCR (co-efficient = -0.001; p = 0.03). CONCLUSION: The recognition of associations may be the first step in the proposal to develop a framework for the surveillance of vision in patients with NIPLHIV. We recommend a study of the sample population to track the stability of these observations before general recommendations for clinical care.


Assuntos
Infecções por HIV , Macula Lutea , Retinite , Adolescente , Adulto , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Humanos , Pessoa de Meia-Idade , Retina , Tomografia de Coerência Óptica/métodos , Adulto Jovem
10.
Front Med (Lausanne) ; 8: 764236, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34901081

RESUMO

Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT). Methods: Macular and optic disc volumetric measurements were performed with individual and combined scan protocols in one eye of 75 healthy subjects. Three repeated measurements were performed with each protocol. From the macular area, retinal thickness in nine different sectors and ganglion cell complex thickness in eight different sectors were analyzed from both scan modes. From the optic disc area, the peripapillary retinal nerve fiber layer (pRNFL) thickness in 12 clock sectors and the optic disc parameters were evaluated. For all the parameters, repeatability limit and agreement analysis were performed. Results: For the retinal thickness measurements in macula, the combined scan had two to three times larger repeatability limit than the individual scan for all the sectors except the central sector, where the repeatability limit was five times larger. The limits of agreement intervals were lower than 20 µm for all sectors, except the central. The ganglion cell complex measurements also had larger repeatability limits for the combined scans, and the limits of agreement intervals were <10 µm for all sectors. For the pRNFL thickness, the repeatability values were distributed like a vertically elongated ellipse for both scans, but still the repeatability was better for individual scan compared to the combined scan. The shortest and widest interval are obtained for sectors 9 (9 µm) and 12 (40 µm), respectively. The repeatability limit was <0.15 units for all disc parameters with both scan modes. Conclusion: The individual macula and optic disc scans had better repeatability than the combined scan mode, and the two scan modes cannot be used interchangeability due to the wide limits of agreement.

11.
Optom Vis Sci ; 98(10): 1183-1195, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34678838

RESUMO

SIGNIFICANCE: Non-immunocompromised people living with HIV (NIPLHIV) share a similar immunocompetence to non-HIV (HIV) people with an elevated cluster of differentiation 4 (CD4) count in the era of antiretroviral therapy (ART). This has reduced the incidence of HIV retinopathy, thus raising the question of the integrity of the retinal morphology in NIPLHIV with longer life expectancy. PURPOSE: The study assessed the retinal thickness and volume of NIPLHIV without retinitis on ART and attempted to find associations with linear parameters of cerebral atrophy. METHODS: The study was conducted at a public hospital in South Africa. All people living with HIV were on ART with CD4 counts above 350 cells/mm3 and viral loads less than 10,000 copies/mL. The Heidelberg Spectralis ocular coherence tomographer assessed the retinal thickness and volume for comparison between 30 NIPLHIV and 30 HIV-negative participants. A subset of the HIV group obtained a computed tomography scan to determine the bicaudate ratio and the sylvian fissure ratio to assess cerebral atrophy. Independent t tests were performed to identify differences in retinal thickness and volume. Multivariate linear regressions measured associations between retinal thickness and volume with cerebral atrophy. RESULTS: The NIPLHIV group had a thicker mean global temporal subfields at Early Treatment Diabetic Retinopathy Study (ETDRS) 3 mm (P = .047) and ETDRS 6 mm (P = .03). The mean global temporal subfield volume at ETDRS 3 mm was also increased in the NIPLHIV group (P = .02). Nasal macula retinal nerve fiber layer thickness and the inferior inner nuclear layer macula volume were directly related to the bicaudate ratio, whereas the volumes at the outer retinal layer subfields of the macula were inversely related to sylvian fissure ratio in NIPLHIV. CONCLUSIONS: Macula thickness and volumetric differences do exist in NIPLHIV. Practitioners should keep NIPLHIV under retinal morphometric surveillance because they live longer. Associations of cerebral atrophy with retinal morphology may be used to monitor cerebral atrophy in NIPLIV on ART.


Assuntos
Retinopatia Diabética , Infecções por HIV , Macula Lutea , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Humanos , Retina , Tomografia de Coerência Óptica
12.
Redox Biol ; 43: 101988, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33932867

RESUMO

Nicotinamide adenine dinucleotide (NAD) is a REDOX cofactor and metabolite essential for neuronal survival. Glaucoma is a common neurodegenerative disease in which neuronal levels of NAD decline. We assess the effects of nicotinamide (a precursor to NAD) on retinal ganglion cells (the affected neuron in glaucoma) in normal physiological conditions and across a range of glaucoma relevant insults including mitochondrial stress and axon degenerative insults. We demonstrate retinal ganglion cell somal, axonal, and dendritic neuroprotection by nicotinamide in rodent models which represent isolated ocular hypertensive, axon degenerative, and mitochondrial degenerative insults. We performed metabolomics enriched for small molecular weight metabolites for the retina, optic nerve, and superior colliculus which demonstrates that ocular hypertension induces widespread metabolic disruption, including consistent changes to α-ketoglutaric acid, creatine/creatinine, homocysteine, and glycerophosphocholine. This metabolic disruption is prevented by nicotinamide. Nicotinamide provides further neuroprotective effects by increasing oxidative phosphorylation, buffering and preventing metabolic stress, and increasing mitochondrial size and motility whilst simultaneously dampening action potential firing frequency. These data support continued determination of the utility of long-term nicotinamide treatment as a neuroprotective therapy for human glaucoma.


Assuntos
Glaucoma , Doenças Neurodegenerativas , Animais , Modelos Animais de Doenças , Humanos , Neuroproteção , Niacinamida , Células Ganglionares da Retina
13.
J Clin Med ; 9(10)2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-33003297

RESUMO

Objective: To evaluate the performance of two subjective refraction measurement algorithms by comparing the refraction values, visual acuity, and the time taken by the algorithms with the standard subjective refraction (SSR). Methods: The SSR and two semi-automated algorithm-based subjective refraction (SR1 and SR2) in-built in the Vision-R 800 phoropter were performed in 68 subjects. In SR1 and SR2, the subject's responses were recorded in the algorithm which continuously modified the spherical and cylindrical component accordingly. The main difference between SR1 and SR2 is the use of an initial fogging step in SR1. Results: The average difference and agreement limits intervals in the spherical equivalent between each refraction method were smaller than 0.25 D, and 2.00 D, respectively. For the cylindrical components, the average difference was almost zero and the agreement limits interval was less than 0.50 D. The visual acuities were not significantly different among the methods. The times taken for SR1 and SR2 were significantly shorter, and SR2 was on average was three times faster than SSR. Conclusions: The refraction values and the visual acuity obtained with the standard subjective refraction and algorithm-based methods were similar on average. The algorithm-based methods were significantly faster than the standard method.

14.
J Clin Med ; 9(10)2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32977411

RESUMO

BACKGROUND: To evaluate the precision and accuracy of objective refraction measurement obtained with combinations of instrument design and technique. We also compared the performance of the instruments with subjective refraction measurements. Method and analysis: The objective refraction was measured in 71 subjects with three autorefractometers that have different designs and measurement principles (binocular with fogging, binocular without fogging, and monocular with fogging). Repeatability and reproducibility metrics were calculated for the objective refraction measurements. The agreement of the objective refraction measurements between the three instruments and the agreement with the subjective refraction measurements were evaluated. RESULTS: All three autorefractometers had repeatability and reproducibility limits smaller than 0.70D. The smallest difference (0.10D) in the spherical equivalent was seen between the two binocular instruments. Compared with the subjective refraction, the binocular without fogging technique had the smallest mean difference in spherical equivalent (<0.20D) whereas the binocular fogging technique had the smallest limit of agreement interval (1.00D). For all comparisons, the mean difference and limit of agreement interval for the cylindrical components were lower than 0.10D and 0.75D, respectively. CONCLUSION: All three instruments evaluated had good repeatability and reproducibility. The binocular fogging technique provided the best agreement with subjective refraction.

15.
Work ; 65(4): 903-914, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32310219

RESUMO

BACKGROUND: Working in front of computer screens is visually demanding and related to adverse eye symptoms. Occurrence of glare further increases visual fatigue. OBJECTIVE: This paper presents results from an examination of visual ergonomics in control room environments at two Swedish process industries. METHODS: Visual conditions were examined and evaluated in nine control rooms and eighteen process operators answered questions about their perceived workload and visual experiences. RESULTS: When working in the control rooms, the mental workload was rated significantly higher by the participants, compared to experienced performance. The operators further experienced significantly higher visual fatigue and blurred vision compared to double vision and sore eyes. Visual demands were increased in conditions where contrast glare was present, as well as frequent changes of focusing distances, and low contrast between background and characters in computer screens. CONCLUSIONS: Suboptimal visual working conditions in the control rooms contributes to increased visual demands on the operators. Presence of glare is leading to visual fatigue and an unnecessary high mental load. The findings support the relevance of considering principles of general and visual ergonomics when designing and organizing work in control rooms. Workstation design should also be flexible to allow for individual and contextual adjustments.


Assuntos
Ergonomia/normas , Fadiga/etiologia , Transtornos da Visão/etiologia , Adulto , Terminais de Computador/normas , Terminais de Computador/estatística & dados numéricos , Ergonomia/estatística & dados numéricos , Fadiga/psicologia , Feminino , Humanos , Iluminação/efeitos adversos , Iluminação/normas , Iluminação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Transtornos da Visão/psicologia , Carga de Trabalho/psicologia , Carga de Trabalho/normas , Carga de Trabalho/estatística & dados numéricos
17.
Mult Scler Relat Disord ; 36: 101414, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31574404

RESUMO

BACKGROUND: Reductions of the peripapillary retinal nerve fiber layer (pRNFL) thickness has been indicated even in early-stages of multiple sclerosis (MS). The aim was to investigate the association between pRNFL thickness, measured with optical coherence tomography (OCT), and physical disability and cognitive impairment in MS. METHODS: 465 MS patients and 168 healthy controls (HCs) were included. MS subjects were divided into subgroups according to disease subtype. All subjects underwent OCT examination of all pRNFL quadrants using Canon OCT-HS100. Associations were tested using linear mixed effect models. Physical disability was assessed with the Expanded Disability Status Scale (EDSS) and cognitive function with the Symbol Digit Modalities Test (SDMT). RESULTS: The average pRNFL, inferior pRNFL and temporal pRNFL thicknesses were significantly correlated to both EDSS (-1.0 µm, p < 0.01; -1.2 µm, p < 0.05; -1.2 µm, p < 0.01) and SDMT (0.1 µm, p < 0.05; 0.2 µm, p < 0.05; 0.2 µm, p < 0.01). A significant thickness loss compared with HCs was seen in the average pRNFL and in all quadrants except for the superior quadrant of primary progressive MS. The largest reduction compared with HCs was seen in the temporal pRNFL of PPMS eyes (-15.8 µm; p < 0.001). CONCLUSION: The reduction of average pRNFL, inferior pRNFL and temporal pRNFL thickness is associated with physical and cognitive disability in MS. We suggest the use of temporal pRNFL as a more sensitive outcome as it showed the strongest association to both EDSS and SDMT.


Assuntos
Disfunção Cognitiva/fisiopatologia , Esclerose Múltipla/patologia , Esclerose Múltipla/fisiopatologia , Neurite Óptica/diagnóstico por imagem , Células Ganglionares da Retina/patologia , Adulto , Idoso , Disfunção Cognitiva/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Fibras Nervosas/patologia , Tomografia de Coerência Óptica
18.
PLoS One ; 14(8): e0221466, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31437222

RESUMO

PURPOSE: To evaluate the repeatability of the new spectral domain optical coherence tomography (HOCT-1F), and also to evaluate the agreement between vertical and horizontal scan protocols. In addition, we also evaluated the relation between the repeatability and age. METHODS: Three consecutive measurements of the inner limiting membrane-retinal pigment epithelium (ILM-RPE), inner limiting membrane-inner plexiform layer (ILM-IPL) from macular horizontal and vertical scans, and inner limiting membrane-retinal nerve fiber layer (ILM-RNFL) from optic disc horizontal scan. 159 subjects were included in the analysis. The within subject standard deviation (Sw) and the repeatability limits (Rlimit) are used to represent the repeatability of the parameters for the different sectors. RESULTS: The Sw for the ILM-RPE thickness was less than 3.5 µm for each sector and scan direction. The Sw values varied within the sectors and scan modes, with horizontal scan modes resulting in better values for the horizontal sectors, and vice versa. The Sw for the GCL-IPL thickness was less than 2 µm, and was similar between the vertical and horizontal scan modes for each sector map. For the optic disc scan, the Sw was not symmetric along the clock-hour map sectors, the largest Sw values were seen in the vertical sectors (8.6 µm). The mean difference between the vertical and horizontal scans was less than 2 µm for each retinal thickness sector map. Significant but weak correlation between the Sw and the subject's age was seen in both macular and optic disc scans. CONCLUSIONS: The repeatability of the HOCT-1F to measure the ILM-RPE-, ILM-IPL- and ILM-RNFL-thickness is good. The repeatability of the ILM-RPE thickness is dependent on the scan direction, which should be taken into account when calculating retinal thickness. There is a weak correlation between the repeatability and the subject's age.


Assuntos
Retina/diagnóstico por imagem , Tomografia de Coerência Óptica , Humanos , Macula Lutea , Reprodutibilidade dos Testes , Epitélio Pigmentado da Retina/diagnóstico por imagem
19.
Med Sci Monit ; 24: 8056-8063, 2018 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-30414377

RESUMO

BACKGROUND To assess the repeatability and agreement between a new high-resolution optical coherence tomographer (OCT) and a Scheimpflug topographer. MATERIAL AND METHODS Sixty phakic and healthy participants were measured in this study, and one eye per participant was analyzed. Depending on their refractive error, each participant was allocated into a myopic, hyperopic, or emmetropic group. The Cirrus HD-OCT 5000 (Carl Zeiss Meditec, Jena, Germany), and the Sirius Scheimpflug topographer (Costruzione Strumenti Oftalmici, Florence, Italy) were used to take all measurements. RESULTS The repeatability of these instruments to measure the anterior chamber depth, angle-to-angle, thinnest pachymetry, and both nasal and temporal angles was smaller than 0.15 mm, 0.40 mm, 10 µm, and 10 degrees, respectively. However, the repeatability of the Scheimpflug instrument to measure the apex pachymetry was about 15 µm, and for the OCT, it was about 4 µm for all groups. On average, the Sirius Scheimpflug instrument measured shallower anterior chamber depth (about 0.10 mm), shorter angle-to-angle (about 0.5 mm), thinner corneas (approximately 10 µm), and narrower angles (around 5 degrees) for all refractive groups. CONCLUSIONS The repeatability of the Cirrus OCT and Sirius Scheimpflug instrument was good and independent of the refractive error. Nevertheless, to judge whether these instruments could be used interchangeable, clinical criteria are needed.


Assuntos
Topografia da Córnea/instrumentação , Topografia da Córnea/métodos , Erros de Refração/diagnóstico , Adulto , Córnea/patologia , Paquimetria Corneana/instrumentação , Paquimetria Corneana/métodos , Emetropia/fisiologia , Feminino , Humanos , Hiperopia/diagnóstico , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico , Fotografação/métodos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA